Magnetic ratings

Printer friendly view Energy product Remanence rev. Temp.- coeff. Coercivity rev. Temp.- coeff. Max. operating temperature Density
(B*H)max. Br of Br HcB HcB HcJ HcJ of HcJ PA 6 3) PA 12 PPS 4) 5)  
 
Hard ferrite magnets, injection moulded 1)   kJ/m3
(typ.)
kJ/m3
(min.)
mT
(typ.)
mT
(min.)
ca. %/K kA/m
(typ.)
kA/m
(min.)
kA/m
(typ.)
kA/m
(min.)
approx. %/K approx. °C approx. °C approx. °C approx. g/cm3
HF 2.5/19 p isotropic   2,5 2,3 120 114 -0,19 80 75 210 190 0,30 120–160 2) 120–140 2) 220 2) 3,2
HF 3/19 p isotropic   3,0 2,9 130 125 -0,19 85 80 210 190 0,30 120–160 2) 120–140 2) 220 2) 3,5
HF 10/22 p anisotropic   11,0 10,0 235 225 -0,19 170 160 230 220 0,30 120–160 2) 120–140 2) 220 2) 3,3
HF 12/22 p anisotropic   13,0 12,0 250 240 -0,19 180 170 230 220 0,30 120–160 2) 120–140 2) 220 2) 3,4
HF 14/22 p anisotropic   14,5 14,0 275 265 -0,19 190 180 230 220 0,30 120–160 2) 120–140 2) 220 2) 3,6
 
Rare earth magnets, injection moulded 1)   kJ/m3
(typ.)
kJ/m3
(min.)
mT
(typ.)
mT
(min.)
ca. %/K kA/m
(typ.)
kA/m
(min.)
kA/m
(typ.)
kA/m
(min.)
approx. %/K approx. °C approx. °C approx. °C approx. g/cm3
NdFeB 30/60 p isotropic   33,0 30,0 435 420 -0,11 6) 305 290 700 600 -0,40 6) 120–140 2) 120–160 2) 4,1
NdFeB 37/60 p isotropic   39,0 37,0 475 465 -0,11 6) 330 320 700 600 -0,40 6) 120–140 2) 120–160 2) 4,5
NdFeB 42/60 p isotropic   44,0 42,0 510 490 -0,11 6) 355 335 700 600 -0,40 6) 120–140 2) 120–160 2) 4,7
NdFeB 48/60 p isotropic   50,0 48,0 540 530 -0,11 6) 375 360 700 600 -0,40 6) 120–140 2) 120–160 2) 4,8
NdFeB 55/60 p isotropic   57,0 55,0 570 560 -0,11 6) 390 375 700 600 -0,40 6) 120–140 2) 120–160 2) 5,2
NdFeB 27/80 p isotropic   29,0 27,0 410 400 -0,13 6) 285 270 900 800 -0,40 6) 120–140 2) 140–180 2) 4,1
NdFeB 32/80 p isotropic   34,0 32,0 445 435 -0,13 6) 310 295 900 800 -0,40 6) 120–140 2) 140–180 2) 4,4
NdFeB 38/80 p isotropic   41,5 38,0 485 470 -0,13 6) 340 320 900 800 -0,40 6) 120–140 2) 140–180 2) 4,7
NdFeB 43/80 p isotropic   46,0 43,0 515 505 -0,13 6) 355 340 900 800 -0,40 6) 120–140 2) 140–180 2) 5,0
NdFeB 46/80 p isotropic   48,0 46,0 530 515 -0,13 6) 365 350 900 800 -0,40 6) 120–140 2) 140–180 2) 5,2
NdFeB 49/80 p isotropic   52,0 49,0 555 545 -0,13 6) 375 365 900 800 -0,40 6) 120–140 2) 140–180 2) 5,3
NdFeB 27/100 p isotropic   29,0 27,0 410 390 -0,12 6) 290 270 1150 1000 -0,40 6) 120–140 2) 120–160 2) 4,3
NdFeB 32/100 p isotropic   34,0 32,0 440 430 -0,12 6) 310 295 1150 1000 -0,40 6) 120–140 2) 120–160 2) 4,6
NdFeB 38/100 p isotropic   41,5 38,0 485 465 -0,12 6) 340 320 1150 1000 -0,40 6) 120–140 2) 120–160 2) 4,9
NdFeB 43/100 p isotropic   46,0 43,0 515 500 -0,12 6) 360 340 1150 1000 -0,40 6) 120–140 2) 120–160 2) 5,2
NdFeB 49/100 p isotropic   51,0 49,0 540 525 -0,12 6) 375 355 1150 1000 -0,40 6) 120–140 2) 120–160 2) 5,3
NdFeB 76/110 p anisotropic   88,0 76,0 700 660 -0,13 6) 490 460 1200 1100 -0,70 6) 100–120 2) 100–120 2) 4,8
 
NdFeB magnets, pressed 1)   kJ/m3
(typ.)
kJ/m3
(min.)
mT
(typ.)
mT
(min.)
ca. %/K kA/m
(typ.)
kA/m
(min.)
kA/m
(typ.)
kA/m
(min.)
approx. %/K approx. °C approx. °C approx. °C approx. g/cm3
NdFeB 55/100 pw isotropic   65,0 55,0 620 580 -0,12 6) 400 380 1100 1000 -0,40 6) 130 2) 6,0
NdFeB 65/85 pw isotropic   72,0 65,0 650 610 -0,13 6) 460 420 950 850 -0,40 6) 140 2) 6,0
NdFeB 72/70 pw isotropic   80,0 72,0 700 660 -0,11 6) 470 440 770 700 -0,40 6) 130 2) 6,0

p: plastic bonded, injection-moulded
pw: plastic bonded, pressed
1) All values were determined with standard samples according to IEC 60404-5. With unusual geometries, especially with thin walls or narrow pole pitches, deviations from the material data can occur.
2) The max. operating temperature depends on the magnet dimension and the specific application. Please contact our application engineering for more information.
3) For binder PA 6 the magnetic values for HcB min./HcB typ. are reduced by -10 kA/m each and HcJ min./HcJ typ. by -30 kA/m each.
4) For magnets with PPS as binder, the chemical resistance to oils, grease, motor oils etc. is significantly better than for PA-bonded magnets; however this has to be checked in individual cases.
5) On request.
6) In the temperature range from 20 °C to 100 °C.

Element "Ba":

Ist die Elementenabkürzung für Barium mit der Ordnungszahl 56 aus der sechsten Periode der zweiten Hauptgruppe im Periodensystem und gehört damit zu den Erdalkalimetallen.

 

Element "Sr":

Ist die Elementenabkürzung für Strontium mit der Ordnungszahl 38 aus der fünften Periode der zweiten Hauptgruppe im Periodensystem und gehört damit zu den Erdalkalimetallen.

 

Isotrop:

Beschreibung für die Unabhängigkeit der Richtung bei einer Eigenschaft.

 

Anisotrop:

Das Gegenteil von Isotrop beschreibt die Abhängigkeit der Richtung einer Eigenschaft.

 

Trockengepresst:

Dies beschreibt den Vorgang, durch den die Magnete hergestellt werden. Trockengepresste Magnete werden aus trockenem Material geformt. Diese Technik wird vorwiegend bei kleinen Formen und Werkstücken angewendet.

 

Nassgepresst:

Dies beschreibt den Vorgang, durch den die Magnete hergestellt werden. Nass gepresste Magnete werden aus nassem Material geformt. Diese Technik erzielt meist bessere magnetische Kennwerte.

Energieproduktion (B*H)max:

Dabei charakterisieren die Endwerte Br (Remanenz), Hc (Koerzitivfeldstärke) und (B·H)max. (Energieprodukt) die wichtigsten magnetischen Eigenschaften eines Dauermagneten. Das größtmögliche Energieprodukt (B·H)max. beschreibt die höchste mit einem Werkstoff erreichbare Energiedichte. Generell gilt: Je größer die Energiedichte, umso kleiner kann bei ansonsten identischen Verhältnissen das für eine bestimmte Aufgabe benötigte Magnetvolumen (V) sein.

 

Remanenz Br:

Unter Remanenz versteht man den zurückbleibenden Magnetismus in einem Teilchen, der nach dem Entfernen des aufmagnetisierten Feldes noch vorhanden ist. Der Begriff Remanenz Br stellt dabei die dazugehörige verbleibende Flussdichte dar. Der zurückbleibende Magnetismus entsteht durch ein zuvor verwendetes Magnetfeld, wie beispielsweise das einer elektrifizierten Spule, das dem Teilchen durch die Induktion ein eigenes Magnetfeld gibt.

 

Rev. Temp. Koeff:

Steht für Reversibler Temperaturkoeffizient und stellt die relative Veränderung einer physikalischen Eigenschaft, in Abhänigkeit zu einer Temperaturveränderung um ein Kelvin.

 

Koerzitivfeldstärke:

Steht für die magnetische Feldstärke, die benötigt wird, um Ferromagnete komplett zu entmagnetisieren. Eine hohe Koerzitivfeldstärke bedeutet, dass ein Magnet länger benötigt um komplett entmagnetisiert zu werden.

 

Max. Betriebstemp.:

Stellt die maximale Temperatur dar, bei der der Magnet noch eingesetzt werden kann.

 

Dichte:

Die Dichte eines Körpers stellt das Verhältnis zwischen Masse und Volumen dar und beschreibt, ob ein Körper verhältnismäßig leicht oder schwer ist.